By Luke Fuhrer, Sarah Beth Thompson, Wesley Porter

It’s that time of year that cotton is being harvested across the state. I just wrote an article for the Georgia Cotton Commission focused on harvest preparation and safety, which can be found here: Cotton Harvest Preparation and Safety – The Georgia Cotton Commission. In addition to safety considerations, if you have a module building picker that has on-board module weighing capabilities, this post provides a guide on how to get that system calibrated so that you can take advantage of the technology.

Click below to see the full publication!

The main goal of this post is to describe how to calibrate the handler weighing system and onboard yield monitor on a John Deere round module building cotton picker. In this post the graphics are from a CP770 model, the steps described apply to models 7760, CP/CS 690, and CS 770 with a few minor images in the graphics or icons. These steps will allow for accurate module weight records and data to calibrate the onboard yield monitor. Both of these systems calibrated will allow for growers to use the data from the machine for future management decisions. The calibration process for the handler and yield monitor is recommended to be completed once per season to ensure accurate model weights. See below overview steps for handler and yield monitor calibration.

Handler Calibration Steps

  1. Start up the machine and allow the hydraulic oil to reach operating temperature. Also, raise and lower the handler a few times to ensure the system contains hydraulic oil at operating temperature prior to calibration. Ensure that the accumulator is empty, no objects are below the handler area, and the machine is at low idle. 
  2. In the cab, select the “Calibrations & Procedures” button on the machine settings screen (marked with a red box in the photo). 
Cotton picker screen with calibration button highlighted

3. On the “Calibrations & Procedures” screen, use the drop-down menu to select “Round Module Weighing Calibration.”

Cotton picker screen with round module weighing calibration button highlighted

4. Initiate the round module weighing calibration procedure by pushing the “Calibrate” button when you are ready.

Cotton picker screen with calibrate button highlighted

5. Leave the cab and safely move to the side of the machine. Locate the handler tether and stand clear of the handler area for safety. Ensure there is no one in the cab or on the machine while you are performing this procedure.

Cotton picker handler secured to the picker for safety

6. Press and hold the “D” button on the tether throughout the entire calibration process.

Option D highlighted on the handler remote

7. The handler will automatically go through the following positions: Storage > Carry > Lower > Carry > Float > Carry > Storage.

Yield Monitor Calibration Steps

1. Start up the machine, ensuring the accumulator is empty. 

2. In the cab, select the “Calibrations & Procedures” button on the machine settings screen (marked with a red box in the photo). 

Cotton picker screen with calibration & procedures button highlighted

3. On the “Calibrations & Procedures” screen, use the drop-down menu to select “Yield Calibration.”

Cotton picker screen with yield calibration button highlighted

4. Begin the yield calibration procedure by pushing the “Calibrate” button.

Cotton picker screen with calibrate button highlighted

5. Begin harvesting cotton, creating a round module as usual. For best results, ensure the crop stand is as uniform as possible across all six rows. 

6. After the module is wrapped and ejected to the handler, select the “HID Cotton Pro” button to find the recorded module weight. 

7. Note or photograph this weight for reference and return to the “Yield Calibration” screen. 

8. Using Equation 1, calculate the actual module weight from the handler weight. Input the actual module weight value into the monitor for the scale weight on the “Yield Calibration” screen. 

9. Save the yield calibration. 

A multistate study by Porter et al. (2022) used 686 modules (1,000–6,000 lb) across the Cotton Belt to develop the following correction equation for the handler weight system: 

\[ \text{Actual Module Weight} = 0.9511 \times \text{handler weight } -\text{ }57.368 \] 

This equation indicates a slight over-measurement by the handler. By applying this correction factor, growers can record accurate module weights.